Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Lancet HIV ; 10(4): e220-e229, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36871568

RESUMO

BACKGROUND: Despite proven benefits for child health, coverage of early infant diagnosis of HIV remains suboptimal in many settings. We aimed to assess the effect of a point-of-care early infant diagnosis test on time-to-results communication for infants vertically exposed to HIV. METHODS: This pragmatic, cluster-randomised, stepped-wedge, open-label trial assessed the effect of the Xpert HIV-1 Qual early infant diagnosis test (Cepheid) on time-to-results communication, compared with standard care laboratory-based testing of dried blood spots using PCR. Hospitals were the unit of randomisation for one-way crossover from control to intervention phase. Each site had between 1 month and 10 months of control phase before transitioning to the intervention, with a total of 33 hospital-months in the control phase and 45 hospital-months in the intervention phase. We enrolled infants vertically exposed to HIV at six public hospitals: four in Myanmar and two in Papua New Guinea. Infants had to have mothers with confirmed HIV infection, be younger than 28 days, and required HIV testing to be eligible for enrolment. Health-care facilities providing prevention of vertical transmission services were eligible for participation. The primary outcome was communication of early infant diagnosis results to the infant's caregiver by 3 months of age, assessed by intention to treat. This completed trial was registered with the Australian and New Zealand Clinical Trials Registry, 12616000734460. FINDINGS: In Myanmar, recruitment took place between Oct 1, 2016, and June 30, 2018; in Papua New Guinea, recruitment was between Dec 1, 2016, and Aug 31, 2018. A total of 393 caregiver-infant pairs were enrolled in the study across both countries. Independent of study time, the Xpert test reduced time to early infant diagnosis results communication by 60%, compared with the standard of care (adjusted time ratio 0·40, 95% CI 0·29-0·53, p<0·0001). In the control phase, two (2%) of 102 study participants received an early infant diagnosis test result by 3 months of age compared with 214 (74%) of 291 in the intervention phase. No safety and adverse events were reported related to the diagnostic testing intervention. INTERPRETATION: This study reinforces the importance of scaling up point-of-care early infant diagnosis testing in resource-constrained and low HIV-prevalence settings, typical of the UNICEF East Asia and Pacific region. FUNDING: National Health and Medical Research Council of Australia.


Assuntos
Infecções por HIV , HIV-1 , Criança , Feminino , Humanos , Lactente , Austrália , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , Infecções por HIV/epidemiologia , Teste de HIV , HIV-1/genética , Mianmar/epidemiologia , Papua Nova Guiné , Análise por Conglomerados
2.
BMJ Open ; 10(11): e043679, 2020 11 19.
Artigo em Inglês | MEDLINE | ID: mdl-33444219

RESUMO

INTRODUCTION: Early infant diagnosis (EID) of HIV and timely initiation of antiretroviral therapy can significantly reduce morbidity and mortality among HIV-positive infants. Access to EID is limited in many low-income and middle-income settings, particularly those in which standard care involves dried blood spots (DBS) sent to centralised laboratories, such as in Papua New Guinea (PNG). We conducted a qualitative exploration of the feasibility and acceptability of implementing a point-of-care (POC) EID test (Xpert HIV-1 Qualitative assay) among health workers and key stakeholders working within the prevention of mother-to-child transmission of HIV (PMTCT) programme in PNG. METHODS: This qualitative substudy was conducted as part of a pragmatic trial to investigate the effectiveness of the Xpert HIV-1 Qualitative test for EID in PNG and Myanmar. Semistructured interviews were undertaken with 5 health workers and 13 key informants to explore current services, experiences of EID testing, perspectives on the Xpert test and the feasibility of integrating and scaling up POC EID in PNG. Coding was undertaken using inductive and deductive approaches, drawing on existing acceptability and feasibility frameworks. RESULTS: Health workers and key informants (N=18) felt EID at POC was feasible to implement and beneficial to HIV-exposed infants and their families, staff and the PMTCT programme more broadly. All study participants highlighted starting HIV-positive infants on treatment immediately as the main advantage of POC EID compared with standard care DBS testing. Health workers identified insufficient resources to follow up infants and caregivers and space constraints in hospitals as barriers to implementation. Participants emphasised the importance of adequate human resources, ongoing training and support, appropriate coordination and a sustainable supply of consumables to ensure effective scale-up of the test throughout PNG. CONCLUSIONS: Implementation of POC EID in a low HIV prevalence setting such as PNG is likely to be both feasible and beneficial with careful planning and adequate resources. TRIAL REGISTRATION NUMBER: 12616000734460.


Assuntos
Infecções por HIV , Sistemas Automatizados de Assistência Junto ao Leito , Diagnóstico Precoce , Estudos de Viabilidade , Feminino , Infecções por HIV/diagnóstico , Infecções por HIV/tratamento farmacológico , Infecções por HIV/transmissão , Humanos , Lactente , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Mianmar , Papua Nova Guiné
3.
Papillomavirus Res ; 6: 70-76, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30391365

RESUMO

The performance of different clinical screening algorithms comprising point-of-care HPV-DNA testing using self-collected vaginal ('V') specimens, and visual inspection of the cervix with acetic acid (VIA) was evaluated in Papua New Guinea. Women aged 30-59 years provided V specimens that were tested at point-of-care using the Xpert HPV Test (Cepheid, Sunnyvale, CA). A clinician-collected cervical ('C') specimen was then collected for point-of-care Xpert testing, and liquid-based cytology (LBC). Following this, VIA examination was conducted, blind to HPV test results, and ablative cervical cryotherapy provided if indicated. Detection of high-grade squamous intraepithelial lesion (HSIL) by LBC was the reference standard used to evaluate clinical screening algorithms. Of 1005 women, 36 had HSIL+. Xpert HPV Test performance using V specimens (sensitivity 91.7%, specificity 87.0%, PPV 34.0%, NPV 99.3%) was superior to VIA examination alone (51.5%, 81.4%, 17.5%, 95.6% respectively) in predicting underlying HSIL+. A screening algorithm comprising V specimen HPV testing followed by VIA examination had low sensitivity (45.5%) but comparable specificity, PPV and NPV to HPV testing alone (96.3%, 45.5%, 96.3% respectively). A 'test-and-treat' screening algorithm based on point-of-care HPV testing of V specimens had superior performance compared with either VIA examination alone, or a combined screening algorithm comprising HPV testing plus VIA.


Assuntos
Técnicas Citológicas/métodos , DNA Viral/isolamento & purificação , Sistemas Automatizados de Assistência Junto ao Leito , Manejo de Espécimes/métodos , Lesões Intraepiteliais Escamosas Cervicais/diagnóstico , Neoplasias do Colo do Útero/diagnóstico , Vagina/virologia , Ácido Acético/administração & dosagem , Adulto , Algoritmos , Colo do Útero/patologia , DNA Viral/genética , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Indicadores e Reagentes , Pessoa de Meia-Idade , Papua Nova Guiné , Autoexame/métodos , Sensibilidade e Especificidade
4.
Malar J ; 14: 412, 2015 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-26480941

RESUMO

BACKGROUND: The diagnosis of malaria during pregnancy is complicated by placental sequestration, asymptomatic infection, and low-density peripheral parasitaemia. Where intermittent preventive treatment (IPT) with sulfadoxine-pyrimethamine is threatened by drug resistance, or is inappropriate due to low transmission, intermittent screening and treatment (ISTp) with rapid diagnostic tests for malaria (RDT) could be a valuable alternative. Therefore, the accuracy of RDTs to detect peripheral and placental infection was assessed in a declining transmission setting in Papua New Guinea (PNG). METHODS: The performance of a combination RDT detecting histidine-rich protein-2 (HRP-2) and Plasmodium lactate dehydrogenase (pLDH), and light microscopy (LM), to diagnose peripheral Plasmodium falciparum and Plasmodium vivax infections during pregnancy, were assessed using quantitative real-time PCR (qPCR) as the reference standard. Participants in a malaria prevention trial in PNG with a haemoglobin ≤90 g/L, or symptoms suggestive of malaria, were tested. Ability of RDT and LM to detect active placental infection on histology was evaluated in some participants. RESULTS: Among 876 women, 1162 RDTs were undertaken (anaemia: 854 [73.5 %], suspected malaria: 308 [26.5 %]). qPCR detected peripheral infection during 190 RDT episodes (165 P. falciparum, 19 P. vivax, 6 mixed infections). Overall, RDT detected peripheral P. falciparum infection with 45.6 % sensitivity (95 % CI 38.0-53.4), a specificity of 96.4 % (95.0-97.4), a positive predictive value of 68.4 % (59.1-76.8), and a negative predictive value of 91.1 % (89.2-92.8). RDT performance to detect P. falciparum was inferior to LM, more so amongst anaemic women (18.6 vs 45.3 % sensitivity, Liddell's exact test, P < 0.001) compared to symptomatic women (72.9 vs 82.4 % sensitivity, P = 0.077). RDT and LM missed 88.0 % (22/25) and 76.0 % (19/25) of P. vivax infections, respectively. In a subset of women tested at delivery and who had placental histology (n = 158) active placental infection was present in 19.6 %: all three peripheral blood infection detection methods (RDT, LM, qPCR) missed >50 % of these infections. CONCLUSIONS: In PNG, HRP-2/pLDH RDTs may be useful to diagnose peripheral P. falciparum infections in symptomatic pregnant women. However, they are not sufficiently sensitive for use in intermittent screening amongst asymptomatic (anaemic) women. These findings have implications for the management of malaria in pregnancy. The adverse impact of infections undetected by RDT or LM on pregnancy outcomes needs further evaluation.


Assuntos
Anemia/diagnóstico , Cromatografia de Afinidade/métodos , Testes Diagnósticos de Rotina/métodos , Malária Falciparum/diagnóstico , Malária Vivax/diagnóstico , Complicações Infecciosas na Gravidez/diagnóstico , Adolescente , Adulto , Antígenos de Protozoários/sangue , Feminino , Humanos , L-Lactato Desidrogenase/sangue , Papua Nova Guiné , Gravidez , Estudos Prospectivos , Proteínas de Protozoários/sangue , Reação em Cadeia da Polimerase em Tempo Real , Sensibilidade e Especificidade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...